Abstract
This paper presents results on the electrochemical behavior of carbon fiber-reinforced polymer (CFRP) composite rods in contact with steel or epoxy coated steel bars in chloride-contaminated concrete. Twelve concrete prisms reinforced by CFRP rods electrically connected to plain or epoxy coated rebars were exposed to 80% humidity for 345 days. Four identical specimens that were not electrically connected served as controls. Measured galvanic currents densities were found to be as much as 100 μA cm−2, raising concerns about the degradation of both CFRP and steel. Electrochemical impedance spectroscopy (EIS) tests were performed to detect possible changes in the electrochemical parameters of CFRP due to galvanic interaction with active steel. Equivalent circuit simulations of the pre- and post-galvanic interaction of CFRP rods with active steel were also evaluated. EIS data indicated that the composite surface was altered so as to have porous electrode characteristics. Optical microscopy provided visible evidence of interface changes on the composite surface, supporting EIS data. The preliminary findings suggest that it would be unwise to permit CFRP to be directly in contact with steel in reinforcing or prestressing applications.
Similar content being viewed by others
References
ACI 440R-96, ‘State-of-the-Art Report on Fiber Reinforced Plastic Reinforcement for Concrete Structures’. American Concrete Institute, Farmington Hills, MI
L.C. Hollaway J. Cadei (2002) Progr. Struct. Eng. Mater 4 131 Occurrence Handle10.1002/pse.112
A.A. Sagüés, ‘Corrosion of Epoxy Coated Rebar in Florida Bridges,’ Final Report to Florida D.O.T., WPI No. 0510603, Available from FDOT Research Center, Tallahassee, FL
A.A. Torres-Acosta, ‘Electrochemical Behavior of Carbon Fiber-Reinforced Plastic (CFRP) Strands in Alkaline Solutions,’ Proceedings XVIII Congress of the Mexican Society of Electrochemistry, Chihuahua, Chihuahua, Mexico, May 26–30, 2003
A.A. Torres-Acosta (2002) J. Compos. Construct 6 112 Occurrence Handle10.1061/(ASCE)1090-0268(2002)6:2(112) Occurrence Handle1:CAS:528:DC%2BD38XjvFGhtLk%3D
A.A. Torres-Acosta, A.A. Sagüés, and R. Sen, Paper No. 98648, 1998 NACE Conference (NACE International, Houston, TX, 1998)
A.A. Torres-Acosta (2002) J. Compos. Construct 6 116 Occurrence Handle10.1061/(ASCE)1090-0268(2002)6:2(116) Occurrence Handle1:CAS:528:DC%2BD38XjvFGhtLc%3D
S. Rizkalla G. Tadros (1994) Concrete Int 16 42 Occurrence Handle1:CAS:528:DyaK2cXlvVGlt74%3D
B.A. Boukamp, ‘Equivalent Circuit (EQUIVCRT.PAS) Users Manual’, University of Twente, Netherlands, Report CT89/214/128, 1989
A.A. Torres-Acosta and A.A. Sagüés, ‘Concrete Cover Cracking due to Corrosion of the Reinforcing Steel’, Proceedings of 5th CANMET/ACI International Conference on Durability of Concrete, (editor V. Malhotra), American Concrete Institute, SP-192, Farmington, Hills, Michigan, USA (2000) pp. 591–611
A.A. Torres-Acosta M. Martínez-Madrid (2003) J. Mater. Civil Eng 15 344 Occurrence Handle10.1061/(ASCE)0899-1561(2003)15:4(344) Occurrence Handle1:CAS:528:DC%2BD3sXlsFKgu70%3D
A.A. Sagüés M.A. Pech-Canul A.K.M. Shahid Al-Mansur (2003) Corrosion Sci 45 7 Occurrence Handle10.1016/S0010-938X(02)00087-2
S.R. Taylor (1994) Compos. Interfaces 2 403 Occurrence Handle1:CAS:528:DyaK2MXmtFalsLk%3D
S.R. Taylor F.D. Wall G.L. Cahen (1996) J. Electrochem. Soc 143 449 Occurrence Handle1:CAS:528:DyaK28Xhtlaisbg%3D
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Torres-Acosta, A., Sen, R. Electrochemical behavior of coupled carbon fiber-reinforced polymer (CFRP) rods in concrete. J Appl Electrochem 35, 529–537 (2005). https://doi.org/10.1007/s10800-005-1318-3
Received:
Revised:
Accepted:
Issue Date: