The effect of pupil dilation on AL-Scan biometric parameters

  • Original Paper
  • Published:
International Ophthalmology Aims and scope Submit manuscript

Abstract

The purpose of this study was to investigate the effects of pupil dilation on the parameters of the AL-Scan (Nidek Co., Ltd, Gamagori, Japan). We compared the measurements of axial length (AL), anterior chamber depth (ACD), central corneal keratometry reading, pupil diameter, and intraocular lens (IOL) power of 72 eyes of 72 healthy volunteers and patients scheduled for cataract surgery before and 45 min after instillation of cyclopentolate hydrochloride 1 % using the AL-Scan. Intraobserver repeatability was assessed by taking three consecutive recordings of ACD and AL. Only ACD readings were significantly different between predilation and postdilation (P < 0.001). The difference of the other measurements between two sessions was not statistically significant (P > 0.001). Only two cases in the study demonstrated changes in IOL power higher than 0.5 D. The intraobserver repeatability of both devices was good (CV values for ACD and AL were 0.16 and 0.20 %, respectively). Dilated pupil size did not affect the measurement of IOL power using the A-Scan optical biometer, but increase in ACD after dilation should be taken into account when performing refractive surgeries in which ACD is very important such as phakic anterior chamber IOL implantation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Haigis W, Lege B, Miller N, Schneider B (2000) Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis. Graefes Arch Clin Exp Ophthalmol 238:765–773

    Article  CAS  PubMed  Google Scholar 

  2. Gallinaro C, Toulemont PJ, Cochener B (1996) Excimer laser photorefractive keratectomy to correct astigmatism. J Cataract Refract Surg 22:557–563

    Article  CAS  PubMed  Google Scholar 

  3. Buckhurst PJ, Wolffsohn JS, Shah S (2009) A new optical low coherence reflectometry device for ocular biometry in cataract patients. Br J Ophthalmol 93:949–953

    Article  CAS  PubMed  Google Scholar 

  4. Holzer MP, Mamusa M, Auffarth GU (2009) Accuracy of a new partial coherence interferometry analyser for biometric measurements. Br J Ophthalmol 93:807–810

    Article  CAS  PubMed  Google Scholar 

  5. Tehrani M, Krummenauer F, Blom E (2003) Evaluation of the practicality of optical biometry and applanation ultrasound in 253 eyes. J Cataract Refract Surg 29:741–746

    Article  PubMed  Google Scholar 

  6. Drexler W, Findl O, Menapace R (1998) Partial coherence interferometry: a novel approach to biometry in cataract surgery. Am J Ophthalmol 126:524–534

    Article  CAS  PubMed  Google Scholar 

  7. Sadiq SA, McElvanney AM (1996) Pupillary dilation and axial length measurement for preoperative assessment of intraocular lens power. Eur J Ophthalmol 6:147–149

    CAS  PubMed  Google Scholar 

  8. Bakbak B, Koktekir BE, Gedik S (2013) The effect of pupil dilation on biometric parameters of the Lenstar 900. Cornea 32(4):e21–e24

    Article  PubMed  Google Scholar 

  9. Wendt M, Croft MA, McDonald J (2008) Lens diameter and thickness as a function of age and pharmacologically stimulated accommodation in rhesus monkeys. Exp Eye Res 86:746–752

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  10. Ostrin LA, Glasser A (2010) Autonomic drugs and the accommodative system in rhesus monkeys. Exp Eye Res 90:104–112

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  11. Palamar M, Egrilmez S, Uretmen O (2011) Influences of cyclopentolate hydrochloride on anterior segment parameters with Pentacam in children. Acta Ophthalmol 89:e461–e465

    Article  PubMed  Google Scholar 

  12. Arriola-Villalobos P, Diaz-Valle D (2014) Effect of pharmacologic pupil dilation on OLCR optical biometry measurements for IOL predictions. Eur J Ophthalmol 24:53–57

    Article  PubMed  Google Scholar 

  13. Holladay JT (1997) Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculations. J Cataract Refract Surg 23:1356–1370

    Article  CAS  PubMed  Google Scholar 

  14. Olsen T, Corydon L, Gimbel H (1995) Intraocular lens power calculation with an improved anterior chamber depth prediction algorithm. J Cataract Refract Surg 21:313–319

    Article  CAS  PubMed  Google Scholar 

  15. Norn M (1985) The effects of drugs on tear flow. Trans Ophthalmol Soc UK 104(Pt 4):410–414

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ertuğrul Can.

Ethics declarations

Conflict of interest

None.

Funding

No financial support was received for this submission.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Can, E., Duran, M., Çetinkaya, T. et al. The effect of pupil dilation on AL-Scan biometric parameters. Int Ophthalmol 36, 179–183 (2016). https://doi.org/10.1007/s10792-015-0097-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10792-015-0097-z

Keywords

Navigation