Operation of the DC Link in the Conditions of Poor Quality of Grid Power

  • Published:
Power Technology and Engineering Aims and scope

The HVDC link at the Trans-Baikal Converter Complex at the 220 kV Mogocha Substation operates under conditions of poor quality of power in the grid. Distortions in a grid are characterized by values of the negative-sequence voltage unbalance factor and voltage THD that are many times higher than the rated values. The operation of STATCOMs, which are part of the HVDC link, has a beneficial effect on the quality of power across the 220 kV buses of the Mogocha Substation. However, a STATCOM is additionally loaded by negative-sequence currents and higher-harmonic currents. A mathematical model was developed and calculations were carried out for various modes of operation to estimate the available power output of the HVDC link in conditions of poor quality of grid power.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. A. Kosolapov and Yu. A. Dement’ev, “Asynchronous DC links for ensuring parallel operation of the interconnected power systems of Siberia and the East,” Énerg. Edinoi Seti, No. 5 (2013).

  2. A. Drozdov, A. Kiselev, I. A. Kosolapov, Yu. G. Shakarian, M. V. Peshkov, and Yu. A. Dementiev, “Operation experience of back-to-back HVDC station based on voltage source converters for interconnection of non-synchronous power systems with significant voltage distortion,” in: B4-308, CIGRE Session 47, Paris (2018).

  3. E. V. Ter-Oganov and A. A. Pyshkin, Power Supply of Railroads [in Russian], Prod. UrEUPS, Yekaterinburg (2014).

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. V. Peshkov.

Additional information

Translated from Élektricheskie Stantsii, No. 1, January 2022, pp. 38 – 48. https://doi.org/10.34831/EP.2022.1086.1.005

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kiselev, A.N., Peshkov, M.V., Plotnikova, T.V. et al. Operation of the DC Link in the Conditions of Poor Quality of Grid Power. Power Technol Eng 56, 280–289 (2022). https://doi.org/10.1007/s10749-023-01507-x

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10749-023-01507-x

Keywords

Navigation