Skip to main content
Log in

Weaning from neonatal and pediatric ECMO with stand-by cannula

  • Brief Communication
  • Artificial Lung / ECMO
  • Published:
Journal of Artificial Organs Aims and scope Submit manuscript

Abstract

The precise moment for weaning a patient off extracorporeal membrane oxygenation (ECMO) is not always easy to establish. Also, mechanical causes may obligate to disconnect the patient from the circuit before the optimal weaning off. In these selected cases, the patient can be disconnected from the circuit and the cannula can be left in place (stand-by cannula) until the patient’s stability without ECMO is assured. The aim was to describe our experience with the stand-by cannula. Single-institution, long-term retrospective study in a pediatric tertiary care hospital. Neonatal and pediatric patients who were under ECMO and needed stand-by cannula before definitive de-cannulation were included. During 18 years, 166 children required ECMO. In 31 patients (18.7%), stand-by cannula was performed before the weaning off. Twenty patients (64.5%) were newborn. The main reason for requiring ECMO in these newborn was persistent pulmonary hypertension. Eleven patients were pediatric and their main cause for requiring ECMO was cardiogenic shock (six patients, 54.4%). The reasons for requiring stand-by cannula were the uncertainty of a successful weaning off in 17 patients (54.8%), to undergo surgery in 10 patients (32.3%) and to replace the circuit in four cases (12.9%). The median duration of stand-by cannula was 12 h (IQR 6–24). Heparinized saline serum was the main maintenance perfusion (28 patients, 90.3%). Three patients needed to restart support with ECMO. Only one mechanical complication was detected. Stand-by cannula is a safe technique, which allows performing a quick re-entrance on ECMO if the weaning off fails.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

References

  1. Robinson S, Peek G. The role of ECMO in neonatal and paediatric patients. Paediatr Child Heal (United Kingdom) [Internet]. Elsevier Ltd. 2019;29:218–23. https://doi.org/10.1016/j.paed.2015.03.005.

    Article  Google Scholar 

  2. Clark JB, Wang S, Palanzo DA, Wise R, Baer LD, Brehm C, et al. Current techniques and outcomes in extracorporeal life support. Artif Organs. 2015;39:926–30.

    Article  Google Scholar 

  3. Holgren SE, Frede RT, Crumley JP, Patel SS, Moore EA, Turek JW. Novel utilization of the bridge during weaning off venoarterial ECMO the Hoffman clamp method. Innov Technol Tech Cardiothorac Vasc Surg. 2016;11:229–31.

    Article  Google Scholar 

  4. Westrope C, Harvey C, Robinson S, Speggiorin S, Faulkner G, Peek GJ. Pump controlled retrograde trial off from VA-ECMO. ASAIO J. 2013;59:517–9.

    Article  Google Scholar 

  5. Pandya NR, Daley M, Mattke A, Shikata F, Betts K, Haisz E, et al. A comparison of pump-controlled retrograde trial off to arterio-venous bridging for weaning from venoarterial extracorporeal membrane oxygenation†. Eur J Cardio-Thoracic Surg. 2019;56:277–84.

    Article  Google Scholar 

Download references

Acknowledgements

Special thanks to the ECMO team of the Hospital Sant Joan de Déu, including surgeons, nurses, and physicians.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sara Bobillo-Perez.

Ethics declarations

Conflict of interest

The authors declare no relevant financial or non financial relationships to disclose.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Susana Segura and Africa Pertierra authors share co-senior authorship.

Supplementary Information

Below is the link to the electronic supplementary material.

Supplementary file1 (DOCX 18 KB)

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Bobillo-Perez, S., Cuaresma, A., Girona-Alarcon, M. et al. Weaning from neonatal and pediatric ECMO with stand-by cannula. J Artif Organs 24, 507–510 (2021). https://doi.org/10.1007/s10047-021-01251-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10047-021-01251-x

Keywords

Navigation