Abstract
Background
Over the years, most of the deep brain stimulation (DBS) complications described have been mainly related to the surgery itself or the stimulation. Only a few authors have dealt with chronic complications or complications due to implanted material.
Methods
We retrospectively analyzed complications beyond the 1st month after surgery in 249 patients undergoing DBS at our site for 16 years, with 321 interventions overall.
Results
Our results show that infection is the most frequent delayed complication (12.5%), the pulse generator being the most common location. Lead breaks (9.3%) are the second most frequent complication. Symptomatic peri-lead edema and cyst formation were exceptional.
Conclusions
The best knowledge about DBS complications allows for better solutions. In case of infection, conservative treatment or partial removal of the DBS system appears to be safe and reasonable. Intracranial complications related to DBS material such as peri-lead edema and cyst formation have a good prognosis. They may appear long after DBS implantation.
Similar content being viewed by others
References
Benabid AL, Chabardes S, Mitrofanis J, Pollak P (2009) Deep brain stimulation of the subthalamic nucleus for the treatment of Parkinson’s disease. Lancet Neurol 8:67e81
Boviatsis EJ, Stavrinou LC, Themistocleous M, Kouyialis AT, Sakas DE (2010) Surgical and hardware complications of deep brain stimulation. A seven-year experience and review of the literature. Acta Neurochir 152:2053–3062
Castro Bouzas D, Serramito García R, Relova Quinteiro JL, Castro García A, Ares Pensado B, Sesar Ignacio A, Gelabert-Gonzalez M (2013) Bowstringing as a complication of deep brain stimulation. Neurocirugia (Astur) 24(1):37–40
Deogaonkar M, Nazzaro JM, Machado A, Rezai A (2011) Transient, symptomatic, post-operative, non-infectious hypodensity around the deep brain stimulation (DBS) electrode. J Clin Neurosci 18(7):910–915
Doshi PK (2011) Long-term surgical and hardware-related complications of deep brain stimulation. Stereotact Funct Neurosurg 89(2):89–95
Englot DJ, Glastonbury CM, Larson PS (2011) Abnormal T2-weighted MRI signal surrounding leads in a subset of deep brain stimulation patients. Stereotact Funct Neurosurg 89(5):311–317
Fenoy AJ, Simpson RK (2012) Management of device-related wound complications in deep brain stimulation surgery. J Neurosurg 116:1324–1332
Follett KA, Weaver FM, Stern M, Hur K, Harris CL, Luo P, Marks WJ Jr, Rothlind J, Sagher O, Moy C, Pahwa R, Burchiel K, Hogarth P, Lai EC, Duda JE, Holloway K, Samii A, Horn S, Bronstein JM, Stoner G, Starr PA, Simpson R, Baltuch G, De Salles A, Huang GD, Reda DJ (2010) Pallidal versus Subthalamic deep-brain stimulation for Parkinson’s disease. N Engl J Med 362:2077–2091
Geissinger G, Neal JH (2007) Spontaneous twiddler’s syndrome in a patient with a deep brain stimulator. Surg Neurol 68:454–456
Jagid J, Madhavan K, Bregy A, Desai M, Ruiz A, Quencer R, Landy HJ (2015) Deep brain stimulation complicated by bilateral cystic cavitation around the leads in a patient with Parkinson’s disease. BMJ Case Rep. doi:10.1136/bcr-2015-211470
Jankovic J (2009) Treatment of hyperkinetic movement disorders. Lancet Neurol 8:844–856
Janson C, Maxwell R, Gupte AA, Abosch A (2010) Bowstringing as a complication of deep brain stimulation: case report. Neurosurgery 66(6):E1205
Ramirez-Zamora A, Levine D, Sommer DB, Dalfino J, Novak P, Pilitsis JG (2013) Intraparenchymal cyst development after deep brain stimulator placement. Stereotact Funct Neurosurg 91(5):338–341
Tong F, Ramirez-Zamora A, Gee L, Pilitsis J (2015) Unusual complications of deep brain stimulation. Neurosurg Rev 38(2):245–252
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Funding
No funding was received for this research.
Conflicts of interest
The authors declare that they have no conflicts of interest.
Ethical aproval and informed consent
For this type of study, formal or informed consent is not required.
Rights and permissions
About this article
Cite this article
Fernández-Pajarín, G., Sesar, A., Ares, B. et al. Delayed complications of deep brain stimulation: 16-year experience in 249 patients. Acta Neurochir 159, 1713–1719 (2017). https://doi.org/10.1007/s00701-017-3252-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00701-017-3252-7