Abstract
Differential pulse anodic stripping voltammetry was applied to detect Pb2+ and Cd2+ at a glassy carbon electrode modified with Nafion, poly(2,5-dimercapto-1,3,4-thiadiazole) (PDMcT), and multiwalled carbon nanotubes (MWCNTs). Preconcentration was accomplished at −1.0 V vs. SCE in pH 5 buffer containing 400 μg L−1 Bi3+ for 6 min and resulted in high sensitivity, selectivity and reproducibility. Electrochemical quartz crystal microbalance studies revealed that PDMcT is cleaved under the reductive conditions to form thiol groups that bind Pb2+ and Cd2+ ions, whilst the Nafion binder stabilizes the film and the MWCNTs improve electroactivity. The presence of the bismuth film improves sensitivity and reproducibility. Under optimum conditions, the electrode responds linearly to Cd2+ ions in the concentration range from 0.05 to 20 μg L−1, and to Pb2+ from 0.1 to 22 μg L−1. The limits of detection (S/N = 3) are 0.03 and 0.05 μg L−1, respectively. This method was successfully applied to the determination of the two ions in water samples.
Similar content being viewed by others
References
Xu H, Zeng L, Xing S, Xian Y, Shi G, Jin L (2008) Ultrasensitive voltammetric detection of trace lead(II) and cadmium(II) using MWCNTs-Nafion/bismuth composite electrodes. Electroanalysis 20:2655
Huang S, Cheng Y, Li B, Liu G (1998) Simultaneous anodic stripping voltammetric determination of lead and cadmium with a carbon paste electrode modified by tributyl phosphate. Microchim Acta 130:97
Hsieh SAK, Chong YS, Tan JF, Ma TS (1982) Determination of lead, mercury, cadmium and thallium in foods by amperometry and by atomic absorption spectrometry. Microchim Acta 78:337
Burlingame AL, Boyd RK, Gaskell SJ (1996) Mass spectrometry. Anal Chem 68:599R
Eksperiandova LP, Blank AB, Makarovskaya YN (2002) Analysis of waste water by x-ray fluorescence spectrometry. X-Ray Spectrom 31:259
Arai Y, Lanzirotti A, Sutton S, Davis JA, Sparks DL (2003) Arsenic speciation and reactivity in poultry litter. Environ Sci Technol 37:4083
Carrégalo S, Merkoçi A, Alegret S (2004) Application of graphite-epoxy composite electrodes in differential pulse anodic stripping voltammetry of heavy metals. Microchim Acta 147:245
Manisankar P, Vedhi C, Selvanathan G, Arumugam P (2008) Differential pulse stripping voltammetric determination of heavy metals simultaneously using new polymer modified glassy carbon electrodes. Microchim Acta 163:289
Mandil A, Idrissi L, Amine A (2010) Stripping voltammetric determination of mercury(II) and lead(II) using screen-printed electrodes modified with gold films, and metal ion preconcentration with thiol-modified magnetic particles. Microchim Acta 170:299
Nagaosa Y, Zong P, Kamio A (2009) Selenium-coated carbon electrode for anodic stripping voltammetric determination of copper(II). Microchim Acta 167:241
Morante-Zarcero S, Sánchez A, Fajardo M, Hierro Id, Sierra I (2010) Voltammetric analysis of Pb(II) in natural waters using a carbon paste electrode modified with 5-mercapto-1-methyltetrazol grafted on hexagonal mesoporous silica. Microchim Acta 169:57
Economou A, Fielden PR (2003) Mercury film electrodes: developments, trends and potentialities for electroanalysis. Analyst 128:205
Song W, Zhang L, Shi L, Li D, Li Y, Long Y (2010) Simultaneous determination of cadmium(II), lead(II) and copper(II) by using a screen-printed electrode modified with mercury nano-droplet. Microchim Acta 169:321
Wang J (2002) Real-time electrochemical monitoring: toward green analytical chemistry. Acc Chem Res 35:811
Wang J, Lu J, Hocevar SB, Farias PAM, Ogorevc B (2000) Bismuth-coated carbon electrodes for anodic stripping voltammetry. Anal Chem 72:3218
Economou A (2005) Bismuth-film electrodes: recent developments and potentialities for electroanalysis. Trends Anal Chem 24:334
Li D, Jia J, Wang J (2010) A study on the electroanalytical performance of a bismuth film-coated and Nafion-coated glassy carbon electrode in alkaline solutions. Microchim Acta 169:221
Zong P, Nagaosa Y (2009) Determination of antimony(III) and (V) in natural water by cathodic stripping voltammetry with in-situ plated bismuth film electrode. Microchim Acta 166:139
Kefala G, Economou A, Voulgaropoulos A (2004) A study of Nafion-coated bismuth-film electrodes for the determination of trace metals by anodic stripping voltammetry. Analyst 129:1082
Kruusma J, Banks CE, Compton RG (2004) Mercury-free sono-electroanalytical detection of lead in human blood by use of bismuth-film-modified boron-doped diamond electrodes. Anal Bioanal Chem 379:700
Kefala G, Economou A, Voulgaropoulos A, Sofoniou M (2003) A study of bismuth-film electrodes for the detection of trace metals by anodic stripping voltammetry and their application to the determination of Pb and Zn in tapwater and human hair. Talanta 61:603
Hocevar SB, Svancara I, Vytras K, Ogorevc B (2005) Novel electrode for electrochemical stripping analysis based on carbon paste modified with bismuth powder. Electrichim Acta 51:706
Cao L, Jia J, Wang Z (2008) Sensitive determination of Cd and Pb by differential pulse stripping voltammetry with in situ bismuth-modified zeolite doped carbon paste electrodes. Electrichim Acta 53:2177
Grobert N (2007) Carbon nanotubes—becoming clean. Mater Today 10:28
Merkoci A (2006) Carbon nanotubes: exciting new materials for microanalysis and sensing. Microchim Acta 152:155
Tan X, Fang M, Chen C, Yu S, Wang X (2008) Counterion effects of nickel and sodium dodecylbenzene sulfonate adsorption to multiwalled carbon nanotubes in aqueous solution. Carbon 46:1741
Li Y-H, Wang S, Luan Z, Ding J, Xu C, Wu D (2003) Adsorption of cadmium(II) from aqueous solution by surface oxidized carbon nanotubes. Carbon 41:1057
Tuzen M, Saygi KO, Soylak M (2008) Solid phase extraction of heavy metal ions in environmental samples on multiwalled carbon nanotubes. J Hazard Mater 152:632
Stafiej A, Pyrzynska K (2007) Adsorption of heavy metal ions with carbon nanotubes. Sep Purif Tech 58:49
Wu K, Hu S, Fei J, Bai W (2003) Mercury-free simultaneous determination of cadmium and lead at a glassy carbon electrode modified with multi-wall carbon nanotubes. Anal Chim Acta 489:215
Hwang GH, Han WK, Park JS, Kang SG (2008) Determination of trace metals by anodic stripping voltammetry using a bismuth-modified carbon nanotube electrode. Talanta 76:301
Liu G, Lin Y, Tu Y, Ren Z (2005) Ultrasensitive voltammetric detection of trace heavy metal ions using carbon nanotube nanoelectrode array. Analyst 1098
Cesarino I, Cavalheiro ÉTG (2008) Thiol-functionalized silica thin film modified electrode in determination of mercury ions in natural water. Electroanalysis 20:2301
Malel E, Sinha KJ, Zawisza I, Wittstock G, Mandler D (2008) Electrochemical detection of Cd2+ ions by a self-assembled monolayer of 1, 9-nonanedithiol on gold. Electrochim Acta 53:6753
Chow E, Hibbert DB, Gooding JJ (2005) Voltammetric detection of cadmium ions at glutathione-modified gold electrodes. Analyst 130:831
Deng W, Tan Y, Xie Q, Li Y, Liang X, Yao S (2009) ABTS-multiwalled carbon nanotubes nanocomposite/Bi film electrode for sensitive determination of Cd and Pb by differential pulse stripping voltammetry. Electroanalysis 21:2477
Love JC, Estroff LA, Kriebel JK, Nuzzo RG, Whitesides GM (2005) Self-assembled monolayers of thiolates on metals as a form of nanotechnology. Chem Rev 105:1103
Shouji E, Yokoyama Y, Pope JM, Oyama N, Buttry DA (1997) Electrochemical and spectroscopic investigation of the influence of acid-base chemistry on the redox properties of 2, 5-dimercapto-1, 3, 4-thiadiazole. J Phys Chem B 101:2861
Tatsuma T, Yokoyama Y, Buttry DA, Oyama N (1997) Electrochemical polymerization and depolymerization of 2, 5-dimercapto-1, 3, 4-thiadiazole. QCM and spectroscopic analysis. J Phys Chem B 101:7556
Naoi K, Oura Y, Iwamizu Y, Oyama N (1995) Electrochemistry of disulfide compounds. J Electrochem Soc 142:354
Fu Y, Zou C, Xie Q, Xu X, Chen C, Deng W, Yao S (2009) Highly sensitive glucose biosensor based on one-pot biochemical preoxidation and electropolymerization of 2, 5-dimercapto-1, 3, 4-thiadiazole in glucose oxidase-containing aqueous suspension. J Phys Chem B 113:1332
Torma F, Kádár M, Tóth K, Tatár E (2008) Nafion®/2, 2′-bipyridyl-modified bismuth film electrode for anodic stripping voltammetry. Anal Chim Acta 619:173
Xing Y, Li L, Chusuei CC, Hull RV (2005) Sonochemical oxidation of multiwalled carbon nanotubes. Langmuir 21:4185
Xie Q, Wang J, Zhou A, Zhang Y, Liu H, Xu Z, Yuan Y, Deng M, Yao S (1999) A study of depletion layer effects on equivalent circuit parameters using an electrochemical quartz crystal impedance system. Anal Chem 71:4649
Dam MER, Schroeder KH (1996) Mercury film electrodes coated with negatively charged polymer films in speciation studies of trace amounts of lead. Electroanalysis 8:1040
Dam MER, Thomsen KN, Pickup PG, Schroder KH (1995) Comparative study of polymer-coated mercury film electrodes for voltammetric analysis of lead and cadmium in the presence of surfactants. Electroanalysis 7:70
Merrifield JD, Davids WG, MacRae JD, Amirbahman A (2004) Uptake of mercury by thiol-grafted chitosan gel beads. Water Res 38:3132
Acknowledgments
This work was supported by the National Natural Science Foundation of China (21075036, 90713018, 20875029), the State Special Scientific Project on Water Treatment (2009ZX07212-001-06), the Foundations of Hunan Provincial Education Department (05K009) and State Key Laboratory of Chemo/Biosensing and Chemometrics (200902).
Author information
Authors and Affiliations
Corresponding author
Electronic supplementary material
Below is the link to the electronic supplementary material.
ESM 1
(DOC 906 kb)
Rights and permissions
About this article
Cite this article
He, X., Su, Z., Xie, Q. et al. Differential pulse anodic stripping voltammetric determination of Cd and Pb at a bismuth glassy carbon electrode modified with Nafion, poly(2,5-dimercapto-1,3,4-thiadiazole) and multiwalled carbon nanotubes. Microchim Acta 173, 95–102 (2011). https://doi.org/10.1007/s00604-010-0541-8
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00604-010-0541-8