Abstract
Purpose
Due to better primary stability and repositioning options, pedicle screws are increasingly used during posterior stabilization of the cervical spine. However, the serious risks generally associated with the insertion of screws in the cervical spine remain. The purpose of this study is to examine the accuracy of pedicle screw insertion with the use of 3D fluoroscopy navigation systems, also accounting for various spine levels.
Methods
Data of 64 patients were collected during and after screw implantation (axial and subaxial) in the cervical spine. 207 screws were implanted from C1 to C7 and analyzed for placement accuracy according to postoperative CT scans and following the modified Gertzbein and Robbins classification.
Results
The accuracy of most of the inserted screws was assessed as grade 2 according to the modified Gertzbein and Robbins classification. 93.9 % of the screws implanted at C1 or C2, and 78.51 % of the screws implanted at levels C3–C7 showed placement accuracy grade 2 or better, indicating pedicle wall perforation of <2 mm. Overall, seven complications were observed. In three cases, the vertebral artery was affected, leading to one fatality. Surgical revision was necessary once because of Magerl screw misplacement and three times due to impaired wound healing. No radicular symptoms resulted from screw malposition.
Conclusion
Axial and subaxial screws can be inserted with a high grade of accuracy using 3D fluoroscopy-based navigation systems. Nevertheless, while this useful innovation helps to minimize the risks of misplacement, the surgery is still a challenge, as arising complications remain severe.
Similar content being viewed by others
References
Abumi K, Itoh H, Taneichi H, Kaneda K (1994) Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: description of the techniques and preliminary report. J Spinal Disord 7(1):19–28
Abumi K, Kaneda K (1997) Pedicle screw fixation for nontraumatic lesions of the cervical spine. Spine 22(16):1853–1863
Abumi K, Shono Y, Ito M, Taneichi H, Kotani Y, Kaneda K (2000) Complications of pedicle screw fixation in reconstructive surgery of the cervical spine. Spine 25(8):962–969
Barnes AH, Eguizabal JA, Acosta FL Jr, Lotz JC, Buckley JM, Ames CP (2009) Biomechanical pullout strength and stability of the cervical artificial pedicle screw. Spine 34(1):E16–E20. doi:10.1097/BRS.0b013e3181891772
Blauth M, Richter M, Lange U (1999) Trans-articular screw fixation of C1/C2 in atlanto-axial instability. Comparison between percutaneous and open procedures. Der Orthopade 28(8):651–661
Dunlap BJ, Karaikovic EE, Park HS, Sokolowski MJ, Zhang LQ (2010) Load sharing properties of cervical pedicle screw-rod constructs versus lateral mass screw-rod constructs. Eur Spine J 19(5):803–808. doi:10.1007/s00586-010-1278-0
Ebraheim NA, Xu R, Knight T, Yeasting RA (1997) Morphometric evaluation of lower cervical pedicle and its projection. Spine 22(1):1–6
Gebauer M, Barvencik F, Briem D, Kolb JP, Seitz S, Rueger JM, Puschel K, Amling M (2010) Evaluation of anatomic landmarks and safe zones for screw placement in the atlas via the posterior arch. Eur Spine J 19(1):85–90. doi:10.1007/s00586-009-1181-8
Gelalis ID, Paschos NK, Pakos EE, Politis AN, Arnaoutoglou CM, Karageorgos AC, Ploumis A, Xenakis TA (2012) Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques. Eur Spine J 21(2):247–255. doi:10.1007/s00586-011-2011-3
Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement in vivo. Spine 15(1):11–14
Glossop ND, Hu RW, Randle JA (1996) Computer-aided pedicle screw placement using frameless stereotaxis. Spine 21(17):2026–2034
Haid RW Jr (2001) C1–C2 transarticular screw fixation: technical aspects. Neurosurgery 49(1):71–74
Ishikawa Y, Kanemura T, Yoshida G, Ito Z, Muramoto A, Ohno S (2010) Clinical accuracy of three-dimensional fluoroscopy-based computer-assisted cervical pedicle screw placement: a retrospective comparative study of conventional versus computer-assisted cervical pedicle screw placement. J Neurosurg Spine 13(5):606–611. doi:10.3171/2010.5.SPINE09993
Ishikawa Y, Kanemura T, Yoshida G, Matsumoto A, Ito Z, Tauchi R, Muramoto A, Ohno S, Nishimura Y (2011) Intraoperative, full-rotation, three-dimensional image (O-arm)-based navigation system for cervical pedicle screw insertion. J Neurosurg Spine 15(5):472–478. doi:10.3171/2011.6.SPINE10809
Kantelhardt SR, Keric N, Giese A (2012) Management of C2 fractures using Iso-C(3D) guidance: a single institution’s experience. Acta Neurochir (Wien) 154(10):1781–1787. doi:10.1007/s00701-012-1443-9
Karaikovic EE, Kunakornsawat S, Daubs MD, Madsen TW, Gaines RW Jr (2000) Surgical anatomy of the cervical pedicles: landmarks for posterior cervical pedicle entrance localization. J Spinal Disord 13(1):63–72
Kosmopoulos V, Schizas C (2007) Pedicle screw placement accuracy: a meta-analysis. Spine 32(3):E111–E120. doi:10.1097/01.brs.0000254048.79024.8b
Lee DH, Lee SW, Kang SJ, Hwang CJ, Kim NH, Bae JY, Kim YT, Lee CS, Daniel Riew K (2011) Optimal entry points and trajectories for cervical pedicle screw placement into subaxial cervical vertebrae. Eur Spine J 20(6):905–911. doi:10.1007/s00586-010-1655-8
Liu YJ, Tian W, Liu B, Li Q, Hu L, Li ZY, Yuan Q, Lu YW, Sun YZ (2010) Comparison of the clinical accuracy of cervical (C2–C7) pedicle screw insertion assisted by fluoroscopy, computed tomography-based navigation, and intraoperative three-dimensional C-arm navigation. Chin Med J 123(21):2995–2998
Ludwig SC, Kramer DL, Vaccaro AR, Albert TJ (1999) Transpedicle screw fixation of the cervical spine. Clin Orthop Relat Res 359:77–88
Luther N, Iorgulescu JB, Geannette C, Gebhard H, Saleh T, Tsiouris AJ, Hartl R (2013) Comparison of navigated versus non-navigated pedicle screw placement in 260 patients and 1434 screws: screw accuracy, screw size, and the complexity of surgery. J Spinal Disord Tech. doi:10.1097/BSD.0b013e31828af33e
Mueller CA, Roesseler L, Podlogar M, Kovacs A, Kristof RA (2010) Accuracy and complications of transpedicular C2 screw placement without the use of spinal navigation. Eur Spine J 19(5):809–814. doi:10.1007/s00586-010-1291-3
Nakashima H, Yukawa Y, Imagama S, Kanemura T, Kamiya M, Yanase M, Ito K, Machino M, Yoshida G, Ishikawa Y, Matsuyama Y, Ishiguro N, Kato F (2012) Complications of cervical pedicle screw fixation for nontraumatic lesions: a multicenter study of 84 patients. J Neurosurg Spine 16(3):238–247. doi:10.3171/2011.11.SPINE11102
Panjabi MM, Shin EK, Chen NC, Wang JL (2000) Internal morphology of human cervical pedicles. Spine 25(10):1197–1205
Richter M, Cakir B, Schmidt R (2005) Cervical pedicle screws: conventional versus computer-assisted placement of cannulated screws. Spine 30(20):2280–2287
Richter M, Mattes T, Cakir B (2004) Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine. Eur Spine J 13(1):50–59. doi:10.1007/s00586-003-0604-1
Richter M, Schmidt R, Claes L, Puhl W, Wilke HJ (2002) Posterior atlantoaxial fixation: biomechanical in vitro comparison of six different techniques. Spine 27(16):1724–1732
Roy-Camille R, Saillant G, Laville C, Benazet JP (1992) Treatment of lower cervical spinal injuries—C3 to C7. Spine 17(10 Suppl):S442–S446
Sakamoto T, Neo M, Nakamura T (2004) Transpedicular screw placement evaluated by axial computed tomography of the cervical pedicle. Spine 29(22):2510–2514 discussion 2515
Schmidt R, Wilke HJ, Claes L, Puhl W, Richter M (2003) Pedicle screws enhance primary stability in multilevel cervical corpectomies: biomechanical in vitro comparison of different implants including constrained and nonconstrained posterior instrumentations. Spine 28(16):1821–1828. doi:10.1097/01.BRS.0000083287.23521.48
Tian W, Liu Y, Zheng S, Lv Y (2013) Accuracy of lower cervical pedicle screw placement with assistance of distinct navigation systems: a human cadaveric study. Eur Spine J 22(1):148–155. doi:10.1007/s00586-012-2494-6
Wang Y, Xie J, Yang Z, Zhao Z, Zhang Y, Li T, Liu L (2013) Computed tomography assessment of lateral pedicle wall perforation by free-hand subaxial cervical pedicle screw placement. Arch Orthop Trauma Surg 133(7):901–909. doi:10.1007/s00402-013-1752-3
Weinstein JN, Spratt KF, Spengler D, Brick C, Reid S (1988) Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine 13(9):1012–1018
Xu R, Ebraheim NA, Skie M (2008) Pedicle screw fixation in the cervical spine. Am J Orthop 37(8):403–408 discussion 408
Yukawa Y, Kato F, Ito K, Nakashima H, Machino M (2009) Anterior cervical pedicle screw and plate fixation using fluoroscope-assisted pedicle axis view imaging: a preliminary report of a new cervical reconstruction technique. Eur Spine J 18(6):911–916. doi:10.1007/s00586-009-0949-1
Zhang HL, Zhou DS, Jiang ZS (2011) Analysis of accuracy of computer-assisted navigation in cervical pedicle screw installation. Orthop Surg 3(1):52–56. doi:10.1111/j.1757-7861.2010.00110.x
Conflict of interest
The authors declare that they have no competing interests. We have no personal or financial conflicts of interest related to the preparation and publication of this manuscript.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Bredow, J., Oppermann, J., Kraus, B. et al. The accuracy of 3D fluoroscopy-navigated screw insertion in the upper and subaxial cervical spine. Eur Spine J 24, 2967–2976 (2015). https://doi.org/10.1007/s00586-015-3974-2
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00586-015-3974-2