Abstract
Complications while removing implants are quite common. In rare cases screw shanks must be left in situ. We present a case of a 38-year-old patient who was treated using a palmar locking plate for a distal radius fracture. After implant removal, one of the screw shanks left in situ penetrated the dorsal cortex of the distal radius into the third extensor tendon compartment and led to irritation of the extensor pollicis longus tendon. We report the unexpected complication and analysis of possible errors of this case to avoid this kind of complication.
References
Arora R, Lutz M, Hennerbichler A et al (2007) Complications followingp internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 21(5):316–322
Hattori Y, Doi K, Sakamoto S et al (2008) Delayed rupture of extensor digitorum communis tendon following volar plating of distal radius fracture. Hand Surg 13(3):183–185
Benson EC, DeCarvalho A, Mikola EA et al (2006) Two potential causes of EPL rupture after distal radius volar plate fixation. Clin Orthop Relat Res. 451:218–222
Björkman A, Jörgsholm P (2004) Rupture of the extensor pollicis longus tendon: a study of aetiological factors. Scand J Plast Reconstr Surg Hand Surg 38(1):32–35
Rozental TD, Blazar PE (2006) Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am 31(3):359–365
Ehlinger M, Adam P, Simon P et al (2009) Technical difficulties in hardware removal in titanium compression plates with locking screws. Orthop Traumatol Surg Res 95(5):373–376
Bae JH, Oh JK, Oh CW et al (2009) Technical difficulties of removal of locking screw after locking compression plating. Arch Orthop Trauma Surg 129(1):91–95
Hamilton P, Doig S, Williamson O (2004) Technical difficulty of metal removal after LISS plating. Injury 35:626–628
Marsh JL, Slongo TF, Agel J et al (2007) Fracture and dislocation classification compendium. J Orthop Trauma 21(10 Suppl.):S1–S133
Orbay JL (2000) The treatment of unstable distal radius fractures with volar fixation. Hand Surg 5(2):103–112
Kirchhoff C, Braunstein, Kirchhoff S et al (2008) Outcome analysis following removal of locking plate fixation of the proximal humerus. BMC Musculoskelet Disord 12(9):138
Jupiter JB, Fernandez DL, Toh CL (1996) The operative management of volar articular fractures of the distal end of the radius. J Bone Joint Surg Am 78:1817–1828
McQueen M, Caspers J (1988) Colles fracture: does the anatomical result affect the final function? J Bone Joint Surg Am 70:649–651
Georgiadis GM, Gove NK, Smith AD et al (2004) Removal of the less invasive stabilization system. J Orthop Trauma 18:562–564
Pichler W, Grechenig W, Clement H et al (2009) Perforation of the third extensor compartment by the drill bit during palmar plating of the distal radius. J Hand Surg Eur Vol 34(3):333–335
Conflict of interest
The authors declare that they have no conflict of interest.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Haug, L.C.P., Deml, C., Blauth, M. et al. Dorsal screw penetration following implant removal after volar locked plating of distal radius fracture. Arch Orthop Trauma Surg 131, 1279–1282 (2011). https://doi.org/10.1007/s00402-011-1300-y
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00402-011-1300-y