Abstract
We demonstrate what is, to our knowledge, the first use of mid-infrared laser absorption spectroscopy for trace-gas measurements of cyclotron target outputs used for the generation of radioactive carbon-11 in positron emission tomography (PET). The spectrometer was based upon a liquid-nitrogen-cooled lead salt diode laser generating single-mode radiation in the wavenumber range of 2230–2240 cm−1. The sample flowed to a multiple-pass optical cell with a total path length of 15.23 m and the laser radiation was detected by two liquid-nitrogen-cooled InSb photodetectors. We present the results of CO, N2O and CO2 measurements on PET trace cyclotron output and discuss future work on 11CO and 11CO2 detection.
Similar content being viewed by others
References
C. Halldin, B. Gulyas, L. Farde, Curr. Pharm. Des. 7, 1907 (2001)
J.S. Fowler, A.P. Wolf, Acc. Chem. Res. 30, 181 (1997)
M. Bergström, A. Grahnén, B. Lånström, Eur. J. Clin. Pharmacol. 59, 357 (2003)
P.A. Martin, Chem. Soc. Rev. 31, 201 (2002)
F.K. Tittel, D. Richter, A. Fried, Top. Appl. Phys. 89, 445 (2003)
V.L. Kasyutich, P.A. Martin, Appl. Phys. B 88, 125 (2007)
P.L. Varghese, R.K. Hanson, J. Quant. Spectrosc. Radiat. Transf. 26, 339 (1981)
H.S. Lowry, C.J. Fisher, J. Quant. Spectrosc. Radiat. Transf. 31, 575 (1984)
R.G. Daniel, K.L. McNesby, A.W. Miziolek, Appl. Opt. 35, 4018 (1996)
L.S. Rothman, D. Jacquemart, A. Barbe, D.C. Benner, M. Birk, L.R. Brown, M.R. Carleer, C. Chackerian Jr., K. Chance, L.H. Coudert, V. Dana, V.M. Devi, J.-M. Flaud, R.R. Gamache, A. Goldman, J.-M. Hartmann, K.W. Jucks, A.G. Maki, J.-Y. Mandin, S.T. Massie et al., J. Quant. Spectrosc. Radiat. Transf. 96, 139 (2005)
S.G. So, G. Wysocki, J.P. Frantz, F.K. Tittel, IEEE Sens. J. 6, 1057 (2006)
B.W.M. Moeskops, H. Naus, S.M. Cristescu, F.J.M. Harren, Appl. Phys. B 82, 649 (2006)
T. Fritsch, P. Hering, M. Mürtz, J. Breath Res. 1, 014002 (2007)
R. Kormann, R. Königstedt, U. Parchatka, J. Lelieveld, H. Fischer, Rev. Sci. Instrum. 76, 075102 (2005)
R. Provencal, M. Gupta, T.G. Owano, D.S. Baer, K.N. Ricci, A. O’Keefe, J.R. Podolske, Appl. Opt. 44, 6712 (2005)
S.C. Van Der Linde, W.P.A. Jansen, J.J.M. De Goeij, L.J. Van Ijzendoorn, F. Kapteijn, Appl. Radiat. Isot. 52, 77 (2000)
M. Schmidt, H. Glatzel-Mattheier, H. Sartorious, D.E. Worthy, I. Levin, J. Geophys. Res. 106, 5507 (2001)
B. Tuzson, M.J. Zeeman, M.S. Zahniser, L. Emmenegger, Infrared Phys. Technol. 51, 198 (2008)
L. Croize, D. Mondelain, C. Camy-Peyret, M. Delmotte, M. Schmidt, Rev. Sci. Instrum. 79, 043101 (2008)
K.P. Petrov, R.F. Curl, F.K. Tittel, Appl. Phys. B 66, 531 (1998)
V.L. Kasyutich, R.J. Holdsworth, P.A. Martin, Appl. Phys. B 92, 271 (2008)
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Kasyutich, V.L., McMahon, A., Barnhart, T. et al. On-line monitoring of cyclotron target-gas output by means of tunable lead salt diode laser absorption spectroscopy. Appl. Phys. B 93, 701–711 (2008). https://doi.org/10.1007/s00340-008-3222-0
Received:
Revised:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00340-008-3222-0