Detection of lesions in multiple sclerosis by 2D FLAIR and single-slab 3D FLAIR sequences at 3.0 T: initial results

  • Neuro
  • Published:
European Radiology Aims and scope Submit manuscript

Abstract

The aim of this study was to compare conventional 2D FLAIR and single-slab 3D FLAIR sequences in the detection of lesions in patients with multiple sclerosis. Eight patients with MS were examined at 3.0 T by using a 2D FLAIR sequence and a single-slab 3D FLAIR sequence. A comparison of lesion detectability was performed for the following regions: periventricular, nonperiventricular/juxtacortical and infratentorial. The contrast-to-noise ratios (CNRs) between lesions and brain tissue and CSF were calculated for each sequence. A total of 424 lesions were found using the 2D FLAIR sequence, while with the 3D FLAIR sequence 719 lesions were found. With the 2D FLAIR sequence, 41% fewer lesions were detected than with the 3D FLAIR sequence. Further, 40% fewer supratentorial and 62.5% fewer infratentorial lesions were found with the 2D FLAIR sequence. In images acquired with the 3D FLAIR sequence, the lesions had significantly higher CNRs than in images acquired with the 2D FLAIR sequence. These are the first results using a single-slab 3D FLAIR sequence at 3.0 T for detection of lesions in patients with MS. With the 3D FLAIR sequence significantly higher CNRs were achieved and significantly more lesions in patients with MS were detected.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Hajnal JV, Bryant DJ, Kasuboski L, Pattany PM, De Coene B, Lewis PD et al (1992) Use of fluid attenuated inversion recovery (FLAIR) pulse sequences in MRI of the brain. J Comput Assist Tomogr 16:841–844

    Article  PubMed  CAS  Google Scholar 

  2. De Coene B, Hajnal JV, Gatehouse P, Longmore DB, White SJ, Oatridge A et al (1992) MR of the brain using fluid-attenuated inversion recovery (FLAIR) pulse sequences. AJNR Am J Neuroradiol 13:1555–1564

    PubMed  Google Scholar 

  3. Tubridy N, Barker GJ, MacManus DG, Moseley IF, Miller DH (1998) Three-dimensional fast fluid attenuated inversion recovery (3D fast FLAIR):a new MRI sequence which increases the detectable cerebral lesion load in multiple sclerosis. Br J Radiol 71:840–845

    PubMed  CAS  Google Scholar 

  4. Tan IL, Pouwels PJW, van Schijndel RA, Adèr HJ, Manoliu RA, Barkhof F (2002) Isotropic 3D fast FLAIR imaging of brain in multiple sclerosis patients: initial experience. Eur Radiol 12:559–567

    PubMed  CAS  Google Scholar 

  5. Tan IL, van Schijndel RA, Pouwels PJW, Adèr HJ, Barkhof F (2002) Serial isotropic three-dimensional fast FLAIR imaging: using image registration and subtraction to reveal active multiple sclerosis lesions. AJR Am J Roentgenol 179:777–782

    PubMed  Google Scholar 

  6. Barker GJB (1998) 3D fast FLAIR: a CSF-nulled 3D fast spin-echo pulse sequence. Magn Reson Imaging 16:715–720

    Article  PubMed  CAS  Google Scholar 

  7. Mugler JP III, Bao S, Mulkern RV, Guttmann CRG, Robertson RL, Jolesz FA, Brookeman JR (2000) Optimized single-slab three-dimensional spin-echo MR imaging of the Brain. Radiology 216:891–899

    PubMed  Google Scholar 

  8. Kallmes DF, Hui FK, Mugler JP III (2001) Suppression of cerebrospinal fluid and blood flow artifacts in FLAIR MR imaging with a single slab three-dimensional pulse sequence: initial experience. Radiology 221:251–255

    Article  PubMed  CAS  Google Scholar 

  9. U.S. Department of Health and Human Services, Food and Drug Administration, Center for Devices and Radiological Health. Guidance for the submission of premarket notifications for magnetic resonance diagnostic devices. Washington, DC: Nov. 14, 1998

  10. Schwindt W, Kugel H, Bachmann R, Allkemper T, Maintz D, Pfleiderer B, Tombach B, Heindel W (2003) Magnetic resonance imaging protocols for examination of the neurocranium at 3T. Eur Radiol 13:2170–2179

    Article  PubMed  CAS  Google Scholar 

  11. Barkhof F, Filippi M, Miller DH et al (1997) Comparison of MRI at first presentation to predict conversion to clinically definite multiple sclerosis. Brain 120:2059–2069

    Article  PubMed  Google Scholar 

  12. McDonald WI, Compston A, Edan G et al (2001) Recommended diagnostic criteria for multiple sclerosis: guidelines from the international panel on the diagnosis of multiple sclerosis. Ann Neurol 50:121–127

    Article  PubMed  CAS  Google Scholar 

  13. Filippi M, Yousry T, Baratti C, Horsfield MA, Mammi S, Becker C et al (1996) Quantitative assessment of MRI lesion load in multiple sclerosis. A comparison of conventional spin-echo with fast fluid-attenuated inversion recovery. Brain 119:1349–1355

    Article  PubMed  Google Scholar 

  14. Bastianello S, Bozzao A, Paolillo A, Giugni E, Gasperini C, Koudriavtseva T et al (1997) Fast spin-echo and fast fluid-attenuated inversion-recovery versus conventional spin-echo sequences for MR quantification of multiple sclerosis lesions. AJNR Am J Neuroradiol 18:699–704

    PubMed  CAS  Google Scholar 

  15. Tubridy N, Barker GJ, MacManus DG, Moseley IF, Miller DH (1998) Optimisation of unenhanced MRI for detection of lesions in multiple sclerosis: a comparison of five pulse sequences with variable slice thickness. Neuroradiology 40:293–297

    Article  PubMed  CAS  Google Scholar 

  16. Herskovits EH, Itoh R, Melhem ER (2001) Accuracy for detection of simulated lesions: comparison of fluid-attenuated inversion-recovery, proton density-weighted, and T2-weighted synthetic brain MR imaging. AJR Am J Roentgenol 118:1313–1318

    Google Scholar 

  17. Melki PS, Mulkern RV (1992) Magnetization transfer effects in multislice RARE sequences. Magn Reson Med 24:189–195

    Article  PubMed  CAS  Google Scholar 

  18. Molyneux PD, Tubridy N, Parker GJM, Barker GJ, MacManus DG, Tofts PS et al (1998) The Effect of section thickness on MR lesion detection and quantification in multiple sclerosis. AJNR Am J Neuroradiol 19:1715–1720

    PubMed  CAS  Google Scholar 

  19. McGowan JC, Patel RS (2000) Technical issues of MRI examination of posterior fossa. J Neurol Sci 172:S20–S42

    Google Scholar 

  20. Stevenson VL, Parker GJM, Barker GJ, Birnie K, Tofts PS, Miller DH, Thompson AJ (2000) Variations in T1 and T2 relaxation times of normal appearing white matter and lesions in multiple sclerosis. J Neurol Sci 178:81–87

    Article  PubMed  CAS  Google Scholar 

  21. Naganawa S, Koshikawa T, Nakamura T, Kawai H, Fukatsu H, Ishigaki T et al (2004) Comparison of flow artifacts between 2D-FLAIR and 3D-FLAIR sequences at 3 T. Eur Radiol 14:1901–1908

    PubMed  Google Scholar 

  22. Lu H, Nagae-Poetscher LM, Golay X, Lin D, Pomper M, Zijl van PCM (2005) Routine clinical brain MRI sequences for use at 3.0 Tesla. J Magn Reson Imaging 22:13–22

    Article  PubMed  Google Scholar 

  23. Busse RF. Equivalent T2-contrast for fast spin echo sequences with low and variable flip refocusing. Proceedings of the International Society for Magnetic Resonance in Medicine 2344; 2005. Thirteenth Meeting, Miami

  24. Papanikolaou N, Papadaki E, Karampekios S (2004) T2 relaxation time analysis in patients with multiple sclerosis: correlation with magnetization transfer ratio. Eur Radiol 14:115–122

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

The authors would like to thank Dr. Gudrun Japp, MD, Department of Neurology, Asklepios Clinic Falkenstein, Asklepiosweg 15, D-61462 Königstein, Germany, for her help in the recruitment of patients. Author J.P.M. was supported in part by NIH grant R01-NS035142 from the National Institute of Neurological Disorders and Stroke.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Andrea Bink.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Bink, A., Schmitt, M., Gaa, J. et al. Detection of lesions in multiple sclerosis by 2D FLAIR and single-slab 3D FLAIR sequences at 3.0 T: initial results. Eur Radiol 16, 1104–1110 (2006). https://doi.org/10.1007/s00330-005-0107-z

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00330-005-0107-z

Keywords

Navigation