Skip to main content
Log in

Efficiency of an implant: new criterion of objective assessment of implants for osteosynthesis of femoral neck fracture

  • SICOT award papers
  • Published:
International Orthopaedics Aims and scope Submit manuscript

Abstract

Purpose

In line with several designs for osteosynthesis of femoral neck fracture (FNF), their effectiveness is still estimated by the results of biomechanical and clinical trials, finite element method (FE). But surgeons require the criteria which would define their properties in advance and allow improve the results of treatment.

Methods

When new implant (NI) is being designed, we developed such criterion – index efficiency of an implant (IEI) – and performed mathematical comparative researches of properties of NI with the known designs. We analyzed the results of comparative clinical trials on treatment of FNF with various implants considering their IEI.

Results

Analysis showed that results of comparative clinical trials with the use of various implants for osteosynthesis FNF completely correlated to their IEI; IEI of the NI two to three times exceeds IEI of all known designs, and the destruction percentage of a bone tissue is two to three times less when it is applied.

Conclusion

The offered IEI can be used for designing new implants and allows improving the results of treatment of patients with FNF by optimizing the choice of implant for osteosynthesis.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5.

Similar content being viewed by others

References

  1. Johnell O, Kanis JA (2004) An estimate of the worldwide prevalence, mortality and disability associated with hip fracture. Osteoporos Int 15:897–902. https://doi.org/10.1007/s00198-004-1627-0

    Article  CAS  PubMed  Google Scholar 

  2. The FAITH Investigatiors (2014) Fixation using alternative implants for the treatment of hip fractures (FAITH): design and rationale for a multi-centre randomized trial comparing sliding hip screws and cancellous screws on revision surgery rates and quality of life in the treatment of femoral neck fractures. BMC Musculoskelet Disord 15:219. https://doi.org/10.1186/1471-2474-15-219

    Article  Google Scholar 

  3. Leonardsson O, Sernbo I, Carlsson A, Akesson K, Rogmark C (2010) Long-term follow-up of replacement compared with internal fixation for displaced femoral neck fractures: results at ten years in a randomised study of 450 patients. J Bone Joint Surg (Br) 9(2):406–412. https://doi.org/10.1302/0301-620X.92B3.23036

    Article  Google Scholar 

  4. Chua D, Jagai SB, Schatzker J (1997) An orthopedic surgeon survey on the treatment of displaced femoral neck fracture: opposing views. Can J Surg 40:271–277

    CAS  PubMed  PubMed Central  Google Scholar 

  5. Masson M, Parker MJ, Fleischer S (2002) Internal fixation versus arthroplasty for intracapsular proximal femoral fractures in adults. Cochrane Database Syst Rev. https://doi.org/10.1002/14651858.CD001708

  6. Bhandari M, Devereaux PJ, Swiontkowski M, Tornetta P, Obremskey W, Koval K, Nork S, Sprague S, Schemitsch E, Guyatt G (2003) Internal fixation compared with arthroplasty for displaced fractures of the femoral neck. J Bone Joint Surg 85A:1673–1681

    Article  Google Scholar 

  7. Elmerson S, Sjostedt A, Zetterberg C (1995) Fixation of femoral neck fracture. A randomized 2-year follow-up study of hook pins and sliding screw plate in 222 patients. Acta Orthop Scand 66:507–510

    Article  CAS  Google Scholar 

  8. Lu-Yao GL, Keller RB, Littenberg B, Wennberg JE (1994) Outcomes after displaced fractures of the femoral neck: a meta-analysis of one hundred and six published reports. J Bone Joint Surg [Am] 76-A:15–25. https://doi.org/10.1055/s-2005-919113

    Article  Google Scholar 

  9. Parker M, Johansen A (2006) Hip fracture. BMJ 333(7557):27–30. https://doi.org/10.1136/bmj.333.7557/27

    Article  PubMed  PubMed Central  Google Scholar 

  10. Jafarov A, Ali-Zadeh C, Özer Z, Mamedov AM, Özbay E (2018) Stress distribution of a new type of perforated implants in femur neck fracture: finite element model. Journal of Physics: Conf. Series 1045:012017. https://doi.org/10.1088/1742-6596/1045/1/012017

    Article  Google Scholar 

  11. Radchenko VP, Nekhozhin AV, Matveev AL (2011) Mathematical modeling of the stressed state of the reinforced bone tissue of the femoral neck with static loads. Vestn.Sam.gos.tehn.un-ta.Ser.Fiz.-mat. Science 4(25):75–81

    Google Scholar 

  12. Strömqvist B, Hansson LI (1984) Femoral head vitality in femoral neck fracture after hook-pin internal fixation. Clin Orthop Relat Res 191:105–109

    Google Scholar 

  13. Strömqvist B, Hansson LI (1983) Avascular necrosis associated with nailing of femoral neck fracture. Two cases examined pre- and postoperatively by tetracycline and radionuclide tracer techniques. Acta Orthop Scand 54(5):687–694

    Article  Google Scholar 

  14. Strömqvist B, Hansson LI, Palmer J, Ceder L, Thorngren KG (1983) Scintimetric evaluation of nailed femoral neck fractures with special reference to type of osteosynthesis. Acta Orthop Scand 54(3):340–347

    Article  Google Scholar 

  15. Gautier E, Ganz K, Krugel N, Gill T, Ganz R (2000) Anatomy of the medial femoral circumflex artery and its surgical implications. The Journal of Bone and Joint Surgery 82-B(5):679–683. doi.org/10.1302/0301-620X.82B5.0820679

    Article  Google Scholar 

  16. Alfredo Brodetti I (1960) Blood supply of the femoral neck and head in relation to the damaging effects of nails and screws. The Journal of Bone and Joint Surgery 42 b(4):794–801

    Article  Google Scholar 

  17. Parker MJ, Gurusamy KS (2001) Internal fixation implants for intracapsular proximal femoral fractures in adults. Cochrane Database Syst Rev. https://doi.org/10.1002/14651858.CD001467

  18. Bhandari M, Tornetta P, Hanson B, Swiontkowski M (2009) Optimal internal fixation for femoral neck fractures: multiple screws or sliding hip screws?Journal of. Orthopaedic Trauma 23(6):403–407. https://doi.org/10.1097/BOT.0b013e318176191f

    Article  Google Scholar 

  19. Chen Z, Wang G, Lin J, Yang T, Fang Y, Liu L, Zhang H (2011) Efficacy comparison between dynamic hip screw combined with anti-rotation screw and cannulated screw in treating femoral neck fractures. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi 25(1):26–29

    PubMed  Google Scholar 

  20. Watson A, Zhang Y, Beattie S, Page RS (2013) Prospective randomized controlled trial comparing dynamic hip screw and screw fixation for undisplaced subcapital hip fractures. ANZ J Surg 83(9):679–683. https://doi.org/10.1111/j.1445-2197.2012.06256.x

    Article  PubMed  Google Scholar 

  21. Griffin XL, Parsons N, Achten J, Costa ML (2014) The Targon femoral neck hip screw versus cannulated screws for internal fixation of intracapsular fractures of the hip: a randomised controlled trial. Bone Joint J. 96-B(5):652–657. https://doi.org/10.1302/0301-620X.96B5.33391

    Article  CAS  PubMed  Google Scholar 

  22. Hou WR, Xu MO (2015) Comparison among three cannulated screws and dynamic hip screw combined with antirotation screw for comminuted fractures of femoral neck. Zhongguo Gu Shang 28(9):796–801

    PubMed  Google Scholar 

  23. Siavashi B, Aalirezaei A, Moosavi M, Golbakhsh MR, Savadkoohi D, Zehtab MJ (2015) A comparative study between multiple cannulated screws and dynamic hip screw for fixation of femoral neck fracture in adults. Int Orthop 39(10):2069–2071. https://doi.org/10.1007/s00264-015-2881-9

    Article  PubMed  Google Scholar 

  24. Eschler A, Brandt S, Gierer P, Mittlmeier T, Gradl G (2014) Angular stable multiple screw fixation (Targon FN) versus standard SHS for the fixation of femoral neck fractures. Injury 45(Suppl 1):76–80. https://doi.org/10.1016/j.injury.2013.10.026

    Article  Google Scholar 

  25. Warschawski Y, Sharfman ZT, Berger O, Steinberg EL, Amar E, Snir N (2016) Dynamic locking plate vs. simple cannulated screws for nondisplaced intracapsular hip fracture: a comparative study. Injury 47(2):424–427. https://doi.org/10.1016/j.injury.2015.10.054

    Article  PubMed  Google Scholar 

  26. Zhang LL, Zhang Y, Ma X, Liu Y (2017) Multiple cannulated screws vs. dynamic hip screws for femoral neck fractures a meta-analysis. Der Orthopade 46(11):954–962

    Article  Google Scholar 

  27. Kaplan T, Akesen B, Demirag B, Bilgen S, Duran K (2012) Comparative results of percutaneous cannulated screws, dynamic compression type plate and screw for the treatment of femoral neck fractures. Turkish Journal of Trauma & Emergency Surgery 18(1):65–70. https://doi.org/10.5505/tjtes.2012.33427

    Article  Google Scholar 

  28. Levi N (1999) Dynamic hip screw versus 3 parallel screws in the treatment of garden 1 + 2 and garden 3 + 4 cervical hip fractures. Panminerva Med Sep 41(3):233–237

    CAS  Google Scholar 

  29. Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) Investigators (2017) Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial. Lancet 389(10078):1519–1527. https://doi.org/10.1016/S0140-6736(17)30066-1

    Article  Google Scholar 

  30. Linke B, Schwieger K, Bursic D, Dutoit C, Ulrich D, Gautier E (2004) Treatment of unstable femoral neck fractures: is the dynamic hip screw a superior alternative to 3 cannulated screws? Poster session presented at: OTA Annual Meeting (Poster 55): 8–10 October 2004. Hollywood: Orthopaedic Trauma Association

  31. Brandt E, Verdonschot N, van Vugt A, van Kampen A (2011) Biomechanical analysis of the sliding hip screw, cannulated screws and Targon FN in intracapsular hip fractures in cadaver femora. Injury 42(2):183–187. https://doi.org/10.1016/j.injury.2010.08.021

    Article  PubMed  Google Scholar 

  32. Kemker B, Magone K, Owen J, Atkinson P, Martin S, Atkinson T (2017) A sliding hip screw augmented with 2 screws is biomechanically similar to an inverted triad of cannulated screws in repair of a Pauwels type-III fracture. Injury 48(8):1743–1748. https://doi.org/10.1016/j.injury.2017.05.013

    Article  CAS  PubMed  Google Scholar 

  33. Ananiev NI, Boykov VP, Merkulova LM, Stolyarov SI, Romanova LP (2003) Some topographic-anatomical and biomechanical features of the structure of the proximal epiphysis of the human femur. Journal of Successes of Modern Science 10:50–51

    Google Scholar 

  34. Hoshino MC, O’Toole RV (2014) Fixed angle devices versus multiple cancellous screws: what does the evidence tell us? Injury 46(3):474–477

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Chingiz Alizade.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict(s) of interest.

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Alizade, C., Jafarov, A., Alizada, F. et al. Efficiency of an implant: new criterion of objective assessment of implants for osteosynthesis of femoral neck fracture. International Orthopaedics (SICOT) 44, 569–575 (2020). https://doi.org/10.1007/s00264-019-04439-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00264-019-04439-2

Keywords

Navigation