Global and regional functional measurements with gated FDG PET in comparison with left ventriculography

  • Original Article
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

The purpose of this study was to validate the measurement of global and regional left ventricular cardiac function with ECG-gated fluorine-18 fluorodeoxyglucose (FDG) positron emission tomography (PET) by comparison with the corresponding indices from X-ray left ventriculography (LVG). Twenty-six patients (23 men, 3 women, mean age 60.4 years) underwent LVG and ECG-gated (eight frames/cycle) FDG-PET within an interval of 10.2±6.8 days. A volumetric sampling approach was used to obtain both global (EF: ejection fraction) and regional [%WT: relative regional count increase from end-diastolic (ED) to end-systolic (ES) phase] functional parameters. The gated PET parameters were compared with the corresponding findings of LVG in seven myocardial segments. EF(gated PET) and EF(LVG) did not differ significantly (30%±10% vs 32%±10%, P=NS). The two EF values correlated significantly, showing no significant systematic measurement bias [EF(gated PET) = 2.61+0.86 × EF(LVG), R=0.84, P<0.0001]. Inter- and intra-observer reproducibility for EF were R=0.95, P<0.0001 and R=0.92, P<0.0001, respectively. Regional function was evaluated with LVG in 144 myocardial segments comprising 35 normokinetic, 70 hypokinetic and 39 a/dyskinetic segments. Visual analysis of LVG and gated PET correlated significantly (P<0.001), with an overall concordance ratio of 58% (83/144, kappa=0.35). Gated PET overestimated the regional function in 27% (39/144) and underestimated it in 15% (22/144). %WT showed significant differences between each pair of groups (a/dyskinesis, 13.2%±9.3%; hypokinesis, 17.1%±8.8%; normokinesis, 21.8%±10.9%). Inter- and intra-observer reproducibility was significant for %WT (R=0.77, P<0.0001 and R=0.79, P<0.0001, respectively). In conclusion, gated FDG PET permits assessment of global left ventricular cardiac function. In addition, assessment of regional function is feasible using the visual or the quantitative parameters.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received 11 July and in revised form 28 October 2000

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hattori, N., Bengel, F.M., Mehilli, J. et al. Global and regional functional measurements with gated FDG PET in comparison with left ventriculography. Eur J Nucl Med 28, 221–229 (2001). https://doi.org/10.1007/s002590000441

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002590000441

Navigation