Abstract
Objective
The aim of this study was to evaluate the sensitivity and specificity of radiographs in identifying incomplete atypical femoral fractures and to determine interobserver and intra-observer reliability.
Materials and methods
Anterior–posterior and lateral radiographs of 10 femurs with incomplete atypical femoral fractures confirmed using bone scintigraphy and magnetic resonance imaging, and 40 femurs without incomplete atypical femoral fractures confirmed using bone scintigraphy, were reviewed by 4 orthopedic surgeons and 4 radiology specialists. Sensitivity, specificity, accuracy, positive predictive value, and negative predictive value were calculated to determine a diagnosis of incomplete atypical femoral fractures. Interobserver reliability was measured using Fleiss’ kappa value, and intra-observer reliability was ascertained using Cohen’s kappa statistic.
Results
Mean sensitivity, specificity, accuracy, and the positive and negative predictive values were found to be 89, 89, 89, 67, and 97% respectively, in diagnosing incomplete atypical femoral fractures using radiographs. Interobserver reliability was found to be at a good level (Fleiss’ kappa = 0.66, standard error = 0.03, 95% confidence interval = 0.61–0.71). Intra-observer Cohen’s kappa values ranged from 0.53 to 0.91.
Conclusion
The use of radiography was satisfactory in identifying incomplete atypical femoral fractures, and the level of interobserver agreement was found to be good. As radiographs are associated with low positive predictive values, an advanced imaging method should be used when an increase in femoral cortical thickness is the only contributory factor to suspicion of an incomplete atypical femoral fracture.
Similar content being viewed by others
References
Burge R, Dawson-Hughes B, Solomon DH, Wong JB, King A, Tosteson A. Incidence and economic burden of osteoporosis-related fractures in the United States, 2005-2025. J Bone Miner Res. 2007;22(3):465–75.
Fischer S, Kapinos KA, Mulcahy A, Pinto L, Hayden O, Barron R. Estimating the long-term functional burden of osteoporosis-related fractures. Osteoporos Int. 2017;28(10):2843–51.
Hopkins RB, Tarride JE, Leslie WD, et al. Estimating the excess costs for patients with incident fractures, prevalent fractures, and nonfracture osteoporosis. Osteoporos Int. 2013;24(2):581–93.
Cummings SR, Cosman F, Lewiecki EM, et al. Goal-directed treatment for osteoporosis: a progress report from the ASBMR-NOF working group on goal-directed treatment for osteoporosis. J Bone Miner Res. 2017;32(1):3–10.
Silverman S, Christiansen C. Individualizing osteoporosis therapy. Osteoporos Int. 2012;23(3):797–809.
Pazianas M, Abrahamsen B. Safety of bisphosphonates. Bone. 2011;49(1):103–10.
Abrahamsen B, Eiken P, Eastell R. Subtrochanteric and diaphyseal femur fractures in patients treated with alendronate: a register-based national cohort study. J Bone Miner Res. 2009;24(6):1095–102.
Clout A, Narayanasamy N, Harris I. Trends in the incidence of atypical femoral fractures and bisphosphonate therapy. J Orthop Surg. 2016;24(1):36–40.
Feldman F. Atypical diaphyseal femoral fractures—new aspects. Skeletal Radiol. 2012;41(1):75–81.
Goh SK, Yang KY, Koh JS, et al. Subtrochanteric insufficiency fractures in patients on alendronate therapy: a caution. J Bone Joint Surg Br. 2007;89(3):349–53.
Odvina CV, Zerwekh JE, Rao DS, Maalouf N, Gottschalk FA, Pak CY. Severely suppressed bone turnover: a potential complication of alendronate therapy. J Clin Endocrinol Metab. 2005;90(3):1294–301.
Shane E, Burr D, Ebeling PR, et al. Atypical subtrochanteric and diaphyseal femoral fractures: report of a task force of the American Society for Bone and Mineral Research. J Bone Miner Res. 2010;25(11):2267–94.
Shane E, Burr D, Abrahamsen B, et al. Atypical subtrochanteric and diaphyseal femoral fractures: second report of a task force of the American Society for Bone and Mineral Research. J Bone Miner Res. 2014;29(1):1–23.
Ng AC, Png MA, Chua DT, Koh JS, Howe TS. Review: epidemiology and pathophysiology of atypical femur fractures. Curr Osteoporos Rep. 2014;12(1):65–73.
Porrino JA Jr, Kohl CA, Taljanovic M, Rogers LF. Diagnosis of proximal femoral insufficiency fractures in patients receiving bisphosphonate therapy. AJR Am J Roentgenol. 2010;194(4):1061–4.
Dell R, Greene D. A proposal for an atypical femur fracture treatment and prevention clinical practice guideline. Osteoporos Int. 2018;29(6):1277–83.
Adams AL, Xue F, Chantra JQ, et al. Sensitivity and specificity of radiographic characteristics in atypical femoral fractures. Osteoporos Int. 2017;28(1):413–7.
Rosenberg ZS, La Rocca Vieira R, Chan SS, et al. Bisphosphonate-related complete atypical subtrochanteric femoral fractures: diagnostic utility of radiography. AJR Am J Roentgenol. 2011;197(4):954–60.
Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33(1):159–74.
Starr J, Tay YKD, Shane E. Current understanding of epidemiology, pathophysiology, and management of atypical femur fractures. Curr Osteoporos Rep. 2018;16(4):519–29.
Matcuk GR Jr, Mahanty SR, Skalski MR, Patel DB, White EA, Gottsegen CJ. Stress fractures: pathophysiology, clinical presentation, imaging features, and treatment options. Emerg Radiol. 2016;23(4):365–75.
Arroll B, Schechter MT, Sheps SB. The assessment of diagnostic tests: a comparison of medical literature in 1982 and 1985. J Gen Intern Med. 1988;3(5):443–7.
Sheps SB, Schechter MT. The assessment of diagnostic tests. A survey of current medical research. JAMA. 1984;252(17):2418–22.
Niimi R, Kono T, Nishihara A, et al. Cortical thickness of the femur and long-term bisphosphonate use. J Bone Miner Res. 2015;30(2):225–31.
Koeppen VA, Schilcher J, Aspenberg P. Atypical fractures do not have a thicker cortex. Osteoporos Int. 2012;23(12):2893–6.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflicts of interest
The authors declare that they have no conflicts of interest.
Ethical approval
All of the procedures performed in this study involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Declaration of Helsinki and its later amendments or comparable ethical standards.
Informed consent
The need to obtain informed consent was waived as this research comprised a retrospective review of the medical records.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Akgun, U., Canbek, U. & Aydogan, N.H. Reliability and diagnostic utility of radiographs in patients with incomplete atypical femoral fractures. Skeletal Radiol 48, 1427–1434 (2019). https://doi.org/10.1007/s00256-019-03212-1
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00256-019-03212-1