Abstract
The flexible surface-coil-type resonator (FSCR) operating in a 700 MHz microwave electron spin resonance (ESR) system was applied to measure the nitroxide radicals at a specific area in rats. The FSCR was composed of a single-turn coil with a diameter of 5 mm and two flexible coaxial lines of 450 mm in length. For an endoscope-like application, the FSCR was inserted into the rectum of the rat and sequential changes in the ESR signals of the intravenously injected nitroxide radical (4-hydroxy-2,2,6,6-tetramethyl-piperidine-1-oxyl; TEMPOL or 3-carbamoyl-2,2,5,5-tetramethyl-pyrrolidine-1-yloxy; carbamoyl-PROXYL) were measured. The ESR signal intensity of the nitroxide decreased according to first-order kinetics. For a stethoscope-like application, the FSCR was placed at several sites on the abdominal skin of the rats receiving a subcutaneous injection of carbamoyl-PROXYL, and diffusion and/or metabolism of the radical in the skin was observed.
Similar content being viewed by others
References
Ohono K, Tsuchihashi N (1991) Advances in electron paramagnetic resonance imaging.Trends Phys Chem 2: 79–97.
Eaton GR, Eaton SS, Ohno K (1991)EPR Imaging and In Vivo EPR. Boca Raton: CRC Press Inc.
Ishida S, Kumashiro H, Tsuchihashi N, et al. (1989)In vivo analysis of nitroxide radicals injected into small animals by L-band ESR technique.Phys Med Biol 34: 1317–1323.
Ishida S, Matsumoto S, Yokoyama H, et al. (1992) An ESR-CT imaging of the head of a living rat receiving an administration of a nitroxide radical.Magn Reson Imaging 10: 21–27.
Yokoyama H, Ogata T, Hiramatsu M, et al. (1996) A spatiotemporal study on the distribution of intraperitoneally injected nitroxide radical in the rat head using anin vivo ESR imaging system.Magn Reson Imaging 14: 559–563.
Oikawa K, Ogata T, Lin Y, et al. (1995) Rapid field scan L-band electron spin resonance computed tomography system using an air-core electromagnet.Anal Sci 11: 885–888.
Kazama S, Takashige G, Yoshioka H, et al. (1996) Dynamic electron spin resonance (ESR) imaging of the distribution of spin labeled dextran in a mouse.Magn Reson Med 36: 547–550.
Yokoyama H, Fujii S, Yoshimura T, et al. (1997)In vivo ESR-CT imaging of the liver in mice receiving subcutaneous injection of nitric oxide-bound iron complex.Magn Reson Imaging 15 (in press).
Quaresima V, Alecci M, Ferrari M, et al. (1992) Whole rat electron paramagnetic resonance imaging of a nitroxide free radical by a radio frequency (280 MHz) spectrometer.Biochem Biophys Res Commun 183: 829–835.
Nishikawa H, Fujii H, Berliner LJ (1985) Helices and surface coils for low-fieldin vivo ESR and EPR imaging applications.J Magn Reson 62: 79–86.
Hirata H, Iwai H, Ono M (1995) Analysis of a flexible surface-coil-type resonator for magnetic resonance measurements.Rev Sci Instrum 66: 4529–4534.
Yuasa T, Watanabe Y, Tamura A, et al. (1996) Development of interactive data processing system forin vivo ESR-CT imaging of bioradicals with L-band microwave.Med Imaging Tech 14: 281–291.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Lin, Y., Yokoyama, H., Ishida, Si. et al. In vivo electron spin resonance analysis of nitroxide radicals injected into a rat by a flexible surface-coil-type resonator as an endoscope- or a stethoscope-like device. MAGMA 5, 99–103 (1997). https://doi.org/10.1007/BF02592239
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02592239