Error rate in five-state myoelectric control systems

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

A myoelectric control system is one in which the operation of a device is controlled by the electric potential produced by voluntary contraction of a muscle. The utilisation of a single muscle site for the 3-state control of a myoelectric prosthesis has proven beneficial for certain amputees. It has been proposed that a single muscle site could be used for 5-state control, perhaps for an elbow and hand. This paper presents a preliminary study of the error probability for 5-state control.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Brittain, R. H. andCaldwell, R. R. (1976) A three-state myoelectric control system. Digest of the 11th International Conference on Medical & Biological Engineering, 20–21.

  • Dorcas, D. S., Dunfield, V. A. andScott, R. N. (1970) Improved myoelectric control system.Med. & Biol. Eng.,8, 333–341.

    Google Scholar 

  • Parker, P. A. (1975) Optimum signal processing for a multistate myoelectric communication channel. Ph.D. thesis, University of New Brunswick.

  • Parker, P. A., Stuller, J. A. andScott, R. N. (1975) Application of decision theory to myoelectric signal processing for control of powered prosthesis. Proceedings of the 28th Annual Conference on Engineering in Medicine and Biology, New Orleans, Louisiana, USA,17, 19.

    Google Scholar 

  • Parker, P. A., Stuller, J. A. andScott, R. N. (1976) Optimum signal set for the multistate myoelectric channel. Digest of the 11th International Conference on Medical & Biological Engineering, 366–367.

  • Parker, P. A., Stuller, J. A. andScott, R. N. (1977) Signal processing for the multistate myoelectric channel.Proc. IEEE,65, 662–674.

    Article  Google Scholar 

  • Scott, R. N., Parker, P. A. andDunfield, V. A. (1974) Myoelectric Control. In IEE Medical Electronics Monographs 7–12,Hill, D. W. andWatson, B. W. (Eds.), 141–169. Peter Peregrinus.

  • Scott, R. N., Paciga, J. E. andParker, P. A. (1978) Operator error in multistate myoelectric control systems.Med. & Biol. Eng. & Comput.,16, 296–301.

    Google Scholar 

  • Scott, R. N., Brittain, R. H., Caldwell, R. R., Cameron, A. B., andDunfield, V. A. (1980) A sensory feedback system compatible with myoelectric control.Med. & Biol. Eng. & Comput.,18, 65–69.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Paciga, J.E., Richard, P.D. & Scott, R.N. Error rate in five-state myoelectric control systems. Med. Biol. Eng. Comput. 18, 287–290 (1980). https://doi.org/10.1007/BF02443381