Treatment of malignant tracheobronchial stenosis by Dacron mesh-covered Z-stents

  • Case Reports
  • Published:
CardioVascular and Interventional Radiology Aims and scope Submit manuscript

Abstract

Z-stents partially covered with an expandable Dacron mesh into which epinephrine and thrombin were infiltrated, were used to reopen both mainstem bronchi, stenosed by bronchogenic carcinoma and to deliver hemostatic agents to the lesion. On follow-up 4 and 6 weeks later, airway patency was retained, the tumor surface was compressed, and the glossy surface of the stent suggested that it was covered with mucosa. For treatment of airway stenosis due to cancer invasion, a stent covered with a Dacron mesh sheet is thought to be effective in compressing the tumor and preventing tumor ingrowth into the stent.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Wallace MJ, Charnsangavej C, Ogawa K, Carrasco CH, Wright KC, McKenna R, McMurtrey M, Gianturco C (1986) Tracheobronchial tree: Expandable metallic stents used in experimental and clinical applications. Work in progress. Radiology 158:309–312

    Google Scholar 

  2. Rousseau HP, Toulouse F, Bilbao IJ, Joffre FG, Chemali RC, Herrero HJ (1991) Use of self-expandable prosthesis in the tracheobronchial tree. RSNA, Chicago

    Google Scholar 

  3. Mair EA, Parsons DS, Lally KP, Van Dellen AF (1991) Comparison of expandable endotracheal stents in the treatment of surgically induced piglet tracheomalacia. Laryngoscope 101(9):1002–1008

    Google Scholar 

  4. Dumon JF (1990) Une endoprosthese tracheobronchique specifique. Rev Mal Resp 7:223–229

    Google Scholar 

  5. Otsuji H, Yoshioka T, Maeda M, Ioka S, Tohjo H, Kushibe K (1991) Treatments of tracheobronchial stenosis by expandable metallic stents. 4th Symposium on Metallic Stents, Oct 5, 1991, Osaka

  6. Oho K, Ogawa I, Amemiya R, Ohtani T, Taira O, Hayata Y (1983) Indications for endoscopic Nd-YAG laser surgery in the trachea and bronchus. Endoscopy 15(5):302–306

    Google Scholar 

  7. Metter FA, Moseley RD (1985) Medical effects of ionizing radiation. Grune and Stratton, Orlando, FL, pp 18–21, 126–146

    Google Scholar 

  8. Freitag L, Chapman GA, Sielczac M, Ahmed A, Russin D (1987) Laser smoke effect on the bronchial system. Lasers Surg Med 7(3):283–288

    Google Scholar 

  9. Ioka S, Tohjo H, Kubota K, Kawahara M, Furuse K, Kitamura S (1991) Use of an expandable metallic stent for carcinomatous bronchial stenosis. J Jpn Soc Bronchol 13:500–505

    Google Scholar 

  10. Tanabe Y, Fujihara Y, Sawada S (1990) Experimental study of endotracheal expandable metallic stent placement. Nihon Igaku Hoshasengakkai Zasshi 50:298–300

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kishi, K., Kobayashi, H., Suruda, T. et al. Treatment of malignant tracheobronchial stenosis by Dacron mesh-covered Z-stents. Cardiovasc Intervent Radiol 17, 33–35 (1994). https://doi.org/10.1007/BF01102069

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01102069

Key words

Navigation