Abstract
Z-stents partially covered with an expandable Dacron mesh into which epinephrine and thrombin were infiltrated, were used to reopen both mainstem bronchi, stenosed by bronchogenic carcinoma and to deliver hemostatic agents to the lesion. On follow-up 4 and 6 weeks later, airway patency was retained, the tumor surface was compressed, and the glossy surface of the stent suggested that it was covered with mucosa. For treatment of airway stenosis due to cancer invasion, a stent covered with a Dacron mesh sheet is thought to be effective in compressing the tumor and preventing tumor ingrowth into the stent.
Similar content being viewed by others
References
Wallace MJ, Charnsangavej C, Ogawa K, Carrasco CH, Wright KC, McKenna R, McMurtrey M, Gianturco C (1986) Tracheobronchial tree: Expandable metallic stents used in experimental and clinical applications. Work in progress. Radiology 158:309–312
Rousseau HP, Toulouse F, Bilbao IJ, Joffre FG, Chemali RC, Herrero HJ (1991) Use of self-expandable prosthesis in the tracheobronchial tree. RSNA, Chicago
Mair EA, Parsons DS, Lally KP, Van Dellen AF (1991) Comparison of expandable endotracheal stents in the treatment of surgically induced piglet tracheomalacia. Laryngoscope 101(9):1002–1008
Dumon JF (1990) Une endoprosthese tracheobronchique specifique. Rev Mal Resp 7:223–229
Otsuji H, Yoshioka T, Maeda M, Ioka S, Tohjo H, Kushibe K (1991) Treatments of tracheobronchial stenosis by expandable metallic stents. 4th Symposium on Metallic Stents, Oct 5, 1991, Osaka
Oho K, Ogawa I, Amemiya R, Ohtani T, Taira O, Hayata Y (1983) Indications for endoscopic Nd-YAG laser surgery in the trachea and bronchus. Endoscopy 15(5):302–306
Metter FA, Moseley RD (1985) Medical effects of ionizing radiation. Grune and Stratton, Orlando, FL, pp 18–21, 126–146
Freitag L, Chapman GA, Sielczac M, Ahmed A, Russin D (1987) Laser smoke effect on the bronchial system. Lasers Surg Med 7(3):283–288
Ioka S, Tohjo H, Kubota K, Kawahara M, Furuse K, Kitamura S (1991) Use of an expandable metallic stent for carcinomatous bronchial stenosis. J Jpn Soc Bronchol 13:500–505
Tanabe Y, Fujihara Y, Sawada S (1990) Experimental study of endotracheal expandable metallic stent placement. Nihon Igaku Hoshasengakkai Zasshi 50:298–300