Skip to main content
Log in

Upgrade of the prompt gamma activation analysis and the neutron-induced prompt gamma spectroscopy facilities at the Budapest research reactor

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

The Budapest Research Reactor’s Prompt Gamma Activation Analysis (PGAA) and Neutron-Induced Prompt gamma Spectroscopy (NIPS) facilities were significantly upgraded during the last few years. The higher neutron flux, achieved by the partial replacement and realignment of the neutron guides, made feasible the automation and specialization of the two experimental stations. A new neutron flux monitor, computer-controlled beam shutters and a low-level counting chamber have been put into operation to assist with in-beam activation experiments. An automatic sample changer has been installed at the PGAA station, while the NIPS station was redesigned and upgraded with a Compton suppressor to use for the non-destructive analysis of bulky samples. In the near future the latter setup will be completed with a neutron tomograph and a moving table, to turn it into a Neutron Radiography/Tomography-driven PGAA equipment.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Paul RL, Lindstrom RM, Brocker C, Mackey EA (2008) J Radioanal Nucl Chem 278:697–701

    Article  CAS  Google Scholar 

  2. Kudejova P, Meierhofer G, Zeitelhack K, Jolie J, Schulze R, Türler A, Materna T (2008) J Radioanal Nucl Chem 278:691–695

    Article  CAS  Google Scholar 

  3. Toh Y, Oshima M, Furutaka K, Kimura A, Koizumi M, Hatsukawa Y, Goto J (2008) J Radioanal Nucl Chem 278:703–706

    Article  CAS  Google Scholar 

  4. Molnár GL, Belgya T, Dabolczi L, Fazekas B, Révay Zs, Veres Á, Bikit I, Kis Z, Östör J (1997) J Radioanal Nucl Chem 215:111–115

    Article  Google Scholar 

  5. Belgya T, Révay Zs, Fazekas B, Héjja I, Dabolczi L, Molnár GL, Kis Z, Östör J, Kaszás Gy (1997) In: Molnár GL, Belgya T, Révay Zs (eds) Proceedings of 9th international symposium on capture gamma-ray spectroscopy and related topics. Budapest, Hungary, Springer Verlag, Budapest/Berlin/Heidelberg, pp 826–837

  6. Rosta L, Belgya T, Cser L, Grosz T, Kaszás Gy, Molnár GL, Révay Zs, Török Gy (1997) Physica B 234:1196–1198

    Article  Google Scholar 

  7. Ember PP, Belgya T, Weil JL, Molnár GL (2002) Appl Radiat Isotopes 57:573–577

    Article  CAS  Google Scholar 

  8. Belgya T, Révay Zs, Molnár GL (2005) J Radioanal Nucl Chem 265:181–191

    Article  CAS  Google Scholar 

  9. Révay Zs, Firestone RB, Belgya T, Molnár GL (2004) Catalog and atlas of prompt gamma rays. In: Molnár GL (ed) Handbook of prompt gamma activation analysis with neutron beams. Kluwer Academic Publishers, Dordrecht/Boston/New York, pp 173–364

    Google Scholar 

  10. Révay Zs, Belgya T, Kasztovszky Zs, Weil JL, Molnár GL (2004) Nucl Instrum Meth B 213:385–388

    Article  Google Scholar 

  11. Révay Zs, Belgya T, Szentmiklósi L, Molnár GL (2005) J Radioanal Nucl Chem 264:277–281

    Article  Google Scholar 

  12. Szentmiklósi L, Révay Zs, Belgya T (2007) Nucl Instrum Meth B 263:90–94

    Article  Google Scholar 

  13. Révay Zs, Belgya T, Szentmiklósi L, Kis Z (2008) J Radioanal Nucl Chem 278:643–646

    Article  Google Scholar 

  14. Belgya T, Kis Z, Szentmiklósi L, Kaszkovszky Zs, Festa G, Andreanelli L, de Pascale MP, Pietro-Palolo A, Kudejova P, Schulze R, Materna T, The Ancient Charm Collaboration (2008) J Radioanal Nucl Chem 278:713–718

    Article  CAS  Google Scholar 

  15. Szentmiklósi L, Berlizov AN (2009) Nucl Instr Meth A 612:122–126

    Article  Google Scholar 

  16. Szentmiklósi L, Révay Zs, Belgya T, Simonits A, Kis Z (2008) J Radioanal Nucl Chem 278:657–660

    Article  Google Scholar 

  17. Révay Zs (2005) J Radioanal Nucl Chem 264:283–287

    Article  Google Scholar 

  18. Szentmiklósi L, Belgya T, Molnár GL, Révay Zs (2007) J Radioanal Nucl Chem 271:439–445

    Article  Google Scholar 

Download references

Acknowledgments

The authors gratefully acknowledge the NKTH NAP VENEUS project (contract no. OMFB-00184/2006) for the financial support and Mr. Kálmán Takács for his technical assistance. The collaboration of the Mirrotron Ltd. is acknowledged in the design and production of the beam shutter.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to László Szentmiklósi.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Szentmiklósi, L., Belgya, T., Révay, Z. et al. Upgrade of the prompt gamma activation analysis and the neutron-induced prompt gamma spectroscopy facilities at the Budapest research reactor. J Radioanal Nucl Chem 286, 501–505 (2010). https://doi.org/10.1007/s10967-010-0765-4

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10967-010-0765-4

Keywords

Navigation