Skip to main content

Advertisement

Log in

Preoperatively determining the margins of subcutaneous malignant soft tissue tumours using contrast-enhanced ultrasonography

  • Technical Notes
  • Published:
Journal of Medical Ultrasonics Aims and scope Submit manuscript

Abstract

The purpose of this technical report is to demonstrate the feasibility of contrast-enhanced ultrasonography for preoperative evaluation of the lateral extent of subcutaneous malignant soft tissue tumours. Patients with subcutaneous malignant soft tissue tumours who underwent surgery between March 2016 and May 2016 were selected for inclusion. Contrast-enhanced ultrasonography using Sonazoid® was performed 1 day before the operation. The tumour margin was determined based on contrast-enhanced ultrasonography and marked on the skin using a permanent marker. After surgery, the extent of the tumour area was determined based on microscopic findings. The distance between the edge of the tumour and the skin markings was histologically measured. The mean distance between the extent of infiltrative tumour growth based on the microscopic findings and the skin marking was 1.3 ± 1.6 mm. The greatest distance between microscopically determined tumour invasion and the skin marking was 4 mm. Contrast-enhanced ultrasonography of subcutaneous malignant soft tissue tumours was not only feasible, but also highly accurate in estimating tumour margins as well as infiltrative tumour growth compared with macroscopic and microscopic analysis, respectively.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

References

  1. Miller KD, Siegel RL, Lin CC, et al. Cancer treatment and survivorship statistics. CA Cancer J Clin. 2016;66:271–89.

    Article  PubMed  Google Scholar 

  2. Widhe B, Bauer HC, Scandinavian Sarcoma G. Surgical treatment is decisive for outcome in chondrosarcoma of the chest wall: a population-based Scandinavian Sarcoma Group study of 106 patients. Thorac Cardiovasc Surg. 2009;137:610–4.

    Article  Google Scholar 

  3. Bellanova L, Paul L, Docquier PL. Surgical guides (patient-specific instruments) for pediatric tibial bone sarcoma resection and allograft reconstruction. Sarcoma. 2013;2013:787653.

    Article  PubMed  PubMed Central  Google Scholar 

  4. Serra-Guillen C, Sanmartin O, Llombart B, et al. Correlation between preoperative magnetic resonance imaging and surgical margins with modified Mohs for dermatofibrosarcoma protuberans. Dermatol Surg. 2011;37:1638–45.

    Article  CAS  PubMed  Google Scholar 

  5. Kikuta K, Kubota D, Yoshida A, et al. An analysis of factors related to the tail-like pattern of myxofibrosarcoma seen on MRI. Skelet Radiol. 2015;44:55–62.

    Article  Google Scholar 

  6. Riouallon G, Larousserie F, Pluot E, Anract P. Superficial myxofibrosarcoma: assessment of recurrence risk according to the surgical margin following resection. A series of 21 patients. Orthop Traumatol Surg Res. 2013;99:473–7.

    Article  CAS  PubMed  Google Scholar 

  7. Yiu-Chiu V, Chiu L. Multiple imaging modalities in the evaluation of musculoskeletal masses. J Comput Tomogr. 1982;6:201–23.

    Article  CAS  PubMed  Google Scholar 

  8. Toprak H, Kilic E, Serter A, Kocakoc E, Ozgocmen S. Ultrasound and Doppler US in evaluation of superficial soft-tissue lesions. J Clin Imaging Sci. 2014;4:12.

    Article  PubMed  PubMed Central  Google Scholar 

  9. Salvatore V, Borghi A, Piscaglia F. Contrast-enhanced ultrasound for liver imaging: recent advances. Curr Pharm Des. 2012;18:2236–52.

    Article  CAS  PubMed  Google Scholar 

  10. Oebisu N, Hoshi M, Ieguchi M, et al. Contrast-enhanced color Doppler ultrasonography increases diagnostic accuracy for soft tissue tumors. Oncol Rep. 2014;32:1654–60.

    Article  PubMed  Google Scholar 

  11. Sehgal CM, Weinstein SP, Arger PH, Conant EF. A review of breast ultrasound. J Mammary Gland Biol Neoplasia. 2006;11:113–23.

    Article  PubMed  Google Scholar 

  12. van Esser S, Veldhuis WB, van Hillegersberg R, et al. Accuracy of contrast-enhanced breast ultrasound for pre-operative tumor size assessment in patients diagnosed with invasive ductal carcinoma of the breast. Cancer Imaging. 2007;7:63–8.

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to Sota Oguro or Kazutaka Kikuta.

Ethics declarations

Ethical statements

All procedures followed were in accordance with the ethical standards of the responsible committee on human experimentation (institutional and national) and with the Helsinki Declaration of 1964 and later versions.

Informed consent

Informed consent was obtained from all patients for being included in the study.

Conflict of interest

The authors declare that there is no conflict of interest.

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Oguro, S., Kikuta, K., Sasaki, A. et al. Preoperatively determining the margins of subcutaneous malignant soft tissue tumours using contrast-enhanced ultrasonography. J Med Ultrasonics 45, 385–388 (2018). https://doi.org/10.1007/s10396-017-0826-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10396-017-0826-1

Keywords

Navigation