Abstract

In this study, the real-time hybrid test using a shaking table for the control performance evaluation of a U-shaped tuned liquid column damper (TLCD) controlling the response of earthquake-excited building structure is experimenttally implemented. In the test, the building structure is used as a numerical part, on which a U-shaped TLCD adopted as an experimental part was installed to reduce its response. At first, the force that is acting between a TLCD and building structure is measured from the load cell attached on shaking table and is fed-back to the computer to control the motion of shaking table. Then, the shaking table is driven such a manner that the error between the interface acceleration computed from the numerical building structure under the excitations of earthquake and the fed-back interface force and that measured from the shaking table. The control efficiency of the TLCD used in this paper is experimentally confirmed by implementing this process of shaking table experiment on real-time.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Horiuchi, T., Inoue, M. and Konno, T., 2000 “Development of a Real-time Hybrid Experimental System Using a Shaking Table”,Proceedings of the twelfth World Conference on Earthquake Engineering, Paper No. 0843.

  • Iemura, H. Igarashi, A. and Takahashi, Y., 1999 “Sub structured Hybrid Techniques for Actuator Loading and Shaking Table Tests”,Proceedings of the first International Conference on Advances in Structural Engineering and Mechanics, pp. 821–826.

  • Igarashi, A., Iemura, H. and Suwa, T, 2000 “Development of Substructured Shaking Table Test Method”,Proceedings of the twelfth World Conference on Earthquake Engineering, Paper No. 1775.

  • Samali, B., Kwok, K. and Gao, H., 1998 “Wind Induced Motion Control of a 76 Storey Building by Liquid Dampers”,Proceedings of Second World Conference on Structural Control, Vol. 1, pp. 1473–1480.

    Google Scholar 

  • Yalla, S. K., 2001, Liquid Dampers for mitigation of structural response: Theoretical Development and Experimental Validation, Ph.D. Thesis, University of Notre Dame, pp. 53–57.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Kyung-Won Min.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lee, SK., Park, E.C., Min, KW. et al. Experimental implementation of a building structure with a tuned liquid column damper based on the real-time hybrid testing method. J Mech Sci Technol 21, 885–890 (2007). https://doi.org/10.1007/BF03027063

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03027063

Keywords

Navigation